Sheep B-cell lymphoma factor 2 (Bcl-2) ELISA Kit


The precision is expressed by the coefficient of variation CV of the measured value of the sample. CV (%) = SD/mean×100 Intra-batch difference: Take the same batch of kits for quantitative detection of low, medium, and high value fixed value samples. Each sample is measured 20 times continuously, and the average value and SD value of samples of different concentrations are calculated.

Contact Person: Anna

Phone:+86 19542779759

Email:Info@idealmedicaltech.com

CONTACT US
  • Product Details
  • Product Video
  • Product Inquiry

Description:

 


Name

Sheep B-cell lymphoma factor 2 (Bcl-2) ELISA Kit

Specifications

96T

article number

HB089-Sp

Species

Sheep

Sample type

serum, plasma, tissue homogenate,cell lysate, cell Culture supernatant etc.

Detection range

See the manual for details

Sensitivity

See the manual for details

Response time

1-5h

Sample volume

10ul

Detection wavelength

450nm

Delivery date

3-5 days

Manual

Consult our salesperson for obtaining

 

Precision

  • The precision is expressed by the coefficient of variation CV of the measured value of the sample. CV (%) = SD/mean×100
  • Intra-batch difference: Take the same batch of kits for quantitative detection of low, medium, and high value fixed value samples. Each sample is measured 20 times continuously, and the average value and SD value of samples of different concentrations are calculated.
  • Inter-batch difference: select 3 different batches of kits to quantitatively determine the low, medium, and high-value fixed value samples. Use the same kit for each sample to repeat the measurement 10 times, and calculate the average value and SD of samples with different concentrations. value6
  • Intra-run difference: CV<4.5%
  • Difference between batches: CV<7.5%

 

Recovery rate

  • The target protein of known concentration was added to 5 different samples, and the recovery experiment was performed to obtain the recovery range and average recovery rate.

 

Sample Type

Range (%)

Average Recovery (%)

Tissue Lysates (n=5)

93-109

97

Serum (n=5)

88-107

94

EDTA plasma (n=5)

85-106

93

Cell culture media (n=5)

92-105

95

 

Linear

  • Add the target protein of known concentration to     5 samples respectively, do recovery experiment, get the range of recovery rate and average recovery rate. Dilute 5 samples by 2 times, 4 times, 8 times, and 16 times respectively for recovery experiments to obtain the recovery range and average recovery rate.

 

Sample

1:2

1:4

1:8

1:16

Tissue Lysates (n=5)

92-105%

84-99%

90-102%

80-93%

Serum (n=5)

81-101%

89-99%

86-98%

83-101%

EDTA plasma (n=5)

85-97%

82-101%

83-96%

79-91%

Cell culture media (n=5)

83-105%

89-112%

81-106%

82-110%

 

Specificity

  • This kit recognizes natural and recombinant Sheep B-cell lymphoma factor 2 (Bcl-2) ,and has no obvious cross-reactivity with other similar substances. Due to the limitation of technology and sample source, it is impossible to complete the cross-reaction test of all related or similar substances. Therefore, this kit may have cross-reaction with other untested substances.

 

Stability

  • It has been determined that the kit must be stored at the recommended temperature within the validity period, and the activity reduction rate is less than 5%. In order to reduce the influence of external factors on the detection value before and after the destruction of the kit, the environmental conditions of the laboratory should be kept as consistent as possible, especially the temperature, humidity and incubation conditions in the laboratory. Secondly, the operation by the same experimenter can reduce human error.

 

Kit composition

 

Serial number

English name

specification

1

Wash solution(30X)

20ml×1 bottle

2

HRP-Conjugate reagent

6ml×1 bottle

3

Microelisa stripplate

12 holes×8 strips

4

Sample diluent

6ml×1 bottle

5

Chromogen Solution A

6ml×1 bottle

6

Chromogen Solution B

6ml×1/bottle

7

Stop solution

6ml×1 bottle

8

Standard

0.5ml×1 bottle

9

Standard diluent

1.5ml×1 bottle

10

Product Description

1 serving

11

Sealing plate membrane

2 sheets

12

Sealing bag

1 piece

 

Note: Please check whether the label and quantity of the reagents in the kit are consistent with the table before use.
Materials and consumables needed but not provided

1. Microplate reader (it is recommended to warm up the instrument before use)
2. Precise pipettes, tips, and sample tanks
3. Distilled or deionized water
4. Bottle washing or automatic plate washing machine
5. 37℃ water bath or thermostat
6. EP tube
7. Powder-free disposable latex gloves

Storage conditions and validity period
1. Store at 2-8℃, do not freeze, the validity period is 6 months.
2. After opening and use, put the coated microplate into a ziplock bag with desiccant, seal the ziplock bag, and put all reagents back into the refrigerator at 2-8°C.

Operation
Submit
%{tishi_zhanwei}%

Message

Submit
%{tishi_zhanwei}%
图片名称

Click to leave a message

If you are interested in our products and want to know more details, please leave a message here and we will get back to you as soon as possible.

Submit
图片名称

+(86)021-63768818

+(86)19542779759

Info@idealmedicaltech.com

Minhang Economic Development Zone, Minhang District, Shanghai

图片名称
二维码

WeChat

Copyright © 2022 Shanghai Ideal Medical Technology Co., Ltd.